If the peristaltic pump is not used for a long time, what should be paid attention to?

If the peristaltic pump is not used for a long time, what should be paid attention to?

1. Check whether the peristaltic pump , pipes, and joints are loose. Rotate the peristaltic pump by hand to test whether the peristaltic pump is flexible.

1.Check whether the peristaltic pump, pipes, and joints are loose. Rotate the peristaltic pump by hand to test whether the peristaltic pump is flexible.

2.Observe that the bearing lubricating oil is added to the bearing body. The oil level should be at the centerline of the oil gauge, and the lubricating oil should be replaced or supplemented in time.

3.Loosen the conversion plug of the peristaltic pump body and inject water.

4.Close the gate valve of the water pipe, the outlet pressure gauge, and the inlet vacuum gauge.

5.Start the jogging motor to ensure that the motor rotates correctly.

6.Start the motor and after the peristaltic pump works normally, open the outlet pressure gauge and the inlet vacuum pump to display the appropriate pressure, and then gradually open the gate valve to check the motor load.

7.To maximize the energy-saving effect, the flow rate and lift of the peristaltic pump must be within the range specified by the road sign, so that the peristaltic pump can work at the most efficient point.

8.When the peristaltic pump is running, the bearing temperature shall not exceed the ambient temperature of 35C, and the maximum temperature shall not exceed 80C.

9.If an abnormal sound is found in the peristaltic pump, stop immediately to find out the cause. 10.To stop using the peristaltic pump, close the gate valve and pressure gauge, then stop the motor.

11.Change the lubricating oil every 100 hours within one month of operation of the peristaltic pump, and change the oil every 500 hours thereafter.

12.Regularly adjust the packing pressure cover to ensure normal water leakage in the packing chamber (water leakage is appropriate.

13.Regularly check the wear of the sleeve, if the wear is large, it should be replaced immediately. 14.When the peristaltic pump is used in winter, the drain plug at the bottom of the pump should be twisted after shutdown to make the medium clean. Cracks that prevent freezing

15.If the peristaltic pump is out of use for a long time, it is necessary to disassemble all the pumps, dry the water, coat the rotating parts and joints with oil, and store them well.

Share: cr peristaltic pump facebook cr peristaltic pump linkedin cr peristaltic pump e-mail

*If you encounter any quality issues, please contact us in time.
*CR tube pump guarantee 7*24 hour online.
*CR manufacturer pump products with one year warranty and lifetime maintenance.
*The product pictures and models, data, functions, performance, specifications and other parameters of this website are for reference only. CR pump may improve the above contents. For details, please refer to the product and product manual. Unless otherwise stated, the data contained in this website are CR pump internal test results, and the comparisons are compared with the CR pump products.

Sounds great but ,I have some questions ,Contact us now !
Verification code:   Can't see clearly? Click to replace Refresh

Link: CR Peristaltic Pump | Peristaltic Pumps for Sale

All rights reserved Baoding Chuangrui Precision Pump Co.,Ltd.    
Address: 2 Floors, East Unit, Building 12, ZOL Innovation Base, Huiyang street, Baoding, Hebei, China.